Device Classification:
We confirm your device class and the correct licensing route before any work begins.
Planning to manufacture medical devices in India? Medwisdom Lifesciences helps manufacturers navigate CDSCO licensing requirements through device classification, technical documentation, application filing, inspection preparation, and post-approval regulatory support.
A medical device manufacturing licence is official approval to make medical devices in India. These devices may include syringes, surgical tools, monitors, and other products used to support patient care.
The Central Drugs Standard Control Organisation (CDSCO) oversees medical device regulation at the national level. State Licensing Authorities also play a key role, depending on the device class and type of application.
The first step is to identify your device and its risk class. This helps you find the correct licence route.

Under the Medical Devices Rules, 2017, devices fall into four risk classes: Class A, Class B, Class C, and Class D. Class A has the lowest risk, while Class D has the highest risk.
The application route depends on your device and manufacturing plan.
The approved licences are issued in Forms MD-5, MD-6, MD-9, and MD-10, as applicable. Certain Class A medical devices that are both non-sterile and non-measuring are exempt from specified licensing requirements, subject to applicable conditions and CDSCO registration requirements. Verify the device against the current official classification list.
Before applying, prepare your business and technical records. These may include company details, manufacturing site information, device specifications, quality management documents, testing reports, labels, and instructions for use.
Your application will also require a comprehensive Site Master File (SMF), Device Master File (DMF), and a Quality Management System aligned with ISO 13485. The exact documents depend on your product and licence type.
Good preparation can help reduce delays caused by missing or unclear information.
The licensing route depends on your device's risk class. Please confirm the current class and forms with us, since classification lists are updated periodically.
| Risk Class | Risk Level | Licensing Authority | Application / licence Forms |
|---|---|---|---|
| Class A | Low | State Licensing Authority | Form MD-3 / MD-5 |
| Class B | Low-moderate | State Licensing Authority | Form MD-3 / MD-5 |
| Class C | Moderate-high | Central Licensing Authority (CDSCO) | Form MD-7 / MD-9 |
| Class D | High | Central Licensing Authority (CDSCO) | Form MD-7 / MD-9 |
Start by checking your product's classification on the official CDSCO website. Next, review the applicable requirements under the Medical Devices Rules, 2017.
Prepare the required documents, submit the application through the relevant online system, pay the applicable fees, and respond to questions from the licensing authority. Your facility and quality systems may also need assessment.
If your business operates in Delhi, areas such as Okhla, Naraina, Bawana, and Mayapuri may be relevant when planning your manufacturing location. However, your exact site and product category determine the applicable requirements.
Medical device rules can be hard to understand when you are busy setting up a factory. A regulatory consultant can help identify the correct license, organise documents, and guide you through the application process.
Choose a consultant who understands your device category and can explain each step clearly. Avoid anyone promising guaranteed approval or a fixed timeline without reviewing your case.
We confirm your device class and the correct licensing route before any work begins.
Manufacturers seeking to produce medical devices for testing, evaluation, examination, demonstration, training, or clinical investigation may need a separate test licence. The application is made in Form MD-12, and the licence is issued in Form MD-13, subject to applicable regulatory requirements.
We prepare and review Device Master Files, Plant Master Files, labelling, Instructions for Use (IFUs), risk management documentation, and applicable test reports.
Gap assessment and quality system documentation aligned with the Fifth Schedule requirements.
We assist with online application submission, applicable fee payments, and responses to regulatory queries throughout the licensing process.
Mock audits and staff briefing so your site is ready for regulatory inspection.
Our consultants work on test, manufacturing and Import Licences for medical device companies of every size, from start-ups to established manufacturers.
We give you a documented plan, regular status updates and honest estimates.
Clients such as Biobee, Imperial Lifesciences and Genes2mer rely on us for compliance support.
We also support registrations in the USA, Europe, the Middle East and other markets as you expand.
Class A and B manufacturers are licensed by the State Licensing Authority. Class C and D manufacturers are licensed by the Central Licensing Authority (CDSCO).
Manufacturers must comply with the applicable Quality Management System requirements under the Fifth Schedule of the Medical Devices Rules, 2017. ISO 13485 can provide a useful framework for establishing and documenting the quality management system. The applicable regulatory requirements should be assessed for the specific device and manufacturing facility. ISO 13485 may support the quality management system, but its precise regulatory role should be assessed for the relevant device and application.
Timelines depend on device class, document readiness and inspection scheduling. We share a realistic estimate after reviewing your product.
A separate test licence may be required when manufacturing medical devices for testing, evaluation, demonstration, or clinical investigation. The applicable requirements depend on the purpose and regulatory pathway. Confirm the relevant provisions and application form under the current Medical Devices Rules, 2017.
Planning to establish a medical device manufacturing facility or obtain a CDSCO manufacturing licence?